EABL_RPLCTN - Meter Reading Document (Replication)
Meter Reading Document (Replication) information is stored in SAP table EABL_RPLCTN.
It is part of development package EE16 in software component IS-U-DM-MR. This development package consists of objects that can be grouped under "IS-U: Meter Reading Order Creation".
It is part of development package EE16 in software component IS-U-DM-MR. This development package consists of objects that can be grouped under "IS-U: Meter Reading Order Creation".
Fields for table EABL_RPLCTN
Field Name | Description | Is Key | Data Element | Data Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | Client | X | MANDT | CLNT | 6 | T000 |
EQUNR | Equipment Number | X | EQUNR | CHAR | 36 | EQUI |
ABLBELNR | Internal ID for meter reading document | X | ABLBELNR | CHAR | 40 | |
GERNR | Device | GERAET | CHAR | 36 | ||
ADAT | Meter reading date relevant to billing | ADAT | DATS | 16 | ||
ATIM | Meter reading time (relevant to billing) | ATIM | CHAR | 8 | ||
V_ZWSTAND | Places Before Decimal Point in Meter Reading | V_ZWSTAND | DEC | 9 | ||
N_ZWSTAND | Places After Decimal Point in the Meter Reading | N_ZWSTAND | DEC | 8 | ||
V_ZWSTNDAB | Predecimal Places in Billed Meter Reading | V_ZWSTNDAB | DEC | 9 | ||
N_ZWSTNDAB | Decimal Places in the Billed Meter Reading | N_ZWSTNDAB | DEC | 8 | ||
MASSREAD | Unit of measurement for meter reading | E_MASSREAD | UNIT | 6 | T006 | |
MASSBILL | Unit of measurement for billing | E_MASSBILL | UNIT | 6 | T006 | |
STANZVOR | Number of predecimal places for register | STANZVORE | NUMC | 4 | ||
STANZNAC | Number of decimal places for register | STANZNACE | NUMC | 4 | ||
SCHAEVER | Estimation procedure | SCHAEVER | CHAR | 4 | ||
SCHAEGR | Estimation reason | SCHAEGR | CHAR | 4 | TE567 | |
AKTIV | Meter reading active | E_AKTIV | CHAR | 2 | ||
ADATSOLL | Scheduled meter reading date | ADATSOLL | DATS | 16 | ||
ADATMAX | Date of maximum meter reading | ADATMAX | DATS | 16 | ||
ATIMMAX | Time of maximum meter reading | ATIMMAX | CHAR | 8 | ||
ADATTATS | Actual meter reading date | ADATTATS | DATS | 16 | ||
ATIMTATS | Actual meter reading time | ATIMTATS | CHAR | 8 | ||
ADATERZ | Meter reading date of implausible meter reading result | ADATERZ | DATS | 16 | ||
ATIMERZ | Meter reading time of implausible meter reading result | ATIMERZ | CHAR | 8 | ||
ADATPROG | Meter reading date from which forecast is made | ADATPROG | DATS | 16 | ||
ATIMPROG | Meter reading time from which consumption is determined | ATIMPROG | CHAR | 8 | ||
THGDATUM | Gas allocation date | THGDATUM | DATS | 16 | ||
PRUEFZAHL | Check number | PRUEFZAHL | NUMC | 4 | ||
BAPERTYP | Base period category | BAPERTYP | CHAR | 2 | ||
ABLSTAT | Meter Reading Status | ABLSTAT | CHAR | 2 | ||
PRUEFPKT | Independent validation | PRUEFPKT | CHAR | 4 | TE218 | |
POPCODE | Dependent validation | POPCODE | CHAR | 4 | TE625 | |
PRUEFTYP | Validation category for meter readings | PRUEFTYP | CHAR | 2 | ||
ABLHINW | Note from meter reader | ABLHINW | CHAR | 8 | TE259 | |
STABLHW | Control of follow-up action for MR result with MR note | STABLHW | CHAR | 4 | ||
KONTRVRF | Indicator: dummy record from automatic control procedure | KONTRVRF | CHAR | 2 | ||
ABLESART | Scheduled meter reading category | GEPLABL | CHAR | 4 | TE614 | |
ABLESER | Meter reader number | ABLESER | CHAR | 6 | TE115 | |
NACHERF | Meter reading result inserted or modified | NACHERF | CHAR | 2 | ||
MDENR | Number for mobile data entry (MDE) | MDENR | NUMC | 6 | ||
MDEUPL | Order has been output | MDEDOWN | CHAR | 2 | ||
E_ZEITVBL | Multiple meter reading order creation | E_ZEITVBL | CHAR | 2 | ||
E_ZVLZUORD | Multiple allocation | E_ZVLZUORD | NUMC | 6 | ||
STEUERGRP | Control group for multiple meter reading order creation | STEUERGRP | CHAR | 8 | TE629 | |
ARBAUF | Control Meter Reading Order ID Printed | ARBAUF | CHAR | 2 | ||
KSTATUS | Status for automatic monitoring of meter reading order | E_KSTATUS | CHAR | 2 | ||
.INCLUDE | ISU_ADMINL | 0 | ||||
ERDAT | Date on which the record was created | ERDAT | DATS | 16 | ||
ERNAM | Name of Person Responsible for Creating the Object | ERNAM | CHAR | 24 | ||
AEDAT | Last Changed On | AEDAT | DATS | 16 | ||
AENAM | Name of Person Who Changed Object | AENAM | CHAR | 24 | ||
ENTRYNUMB | Entry number for fast entry | ENTRYNUMB | NUMC | 16 | ||
ACTOR | Concatinated Identification (Type and ID) of Org. Objects | HROBJEC_14 | CHAR | 28 | ||
ISTABLART | Meter reading type | ISTABLART | CHAR | 4 | TE436 | |
ABLESTYP | Meter reading category | ABLESTYP | CHAR | 4 | TE614 | |
E_ZVBL_BEZDAT | Scheduled meter reading date for base meter reading | E_ZVBL_BEZDAT | DATS | 16 | ||
SM_AUFNR | Service order or notification | PM_SVCNR | CHAR | 24 | ||
DOC_TYPE | Document category for plant maintenance and customer service | KZ_SM_DOC_TYPE | CHAR | 2 | ||
.INCLUDE | EABL_JBP | 0 | ||||
ADATREAL | [JBP] Real Meter Reading Date | ADATREAL | DATS | 16 | ||
ATIMREAL | [JBP] Real Meter Reading Time | ATIMREAL | CHAR | 8 | ||
S_ISTABLART | [JBP] Meter Reading Type for Original Meter Reading | S_ISTABLART | CHAR | 4 | ||
S_AKTIV | [JBP] Orig. Meter Reading: Meter Reading Active | S_AKTIV | CHAR | 2 | ||
S_ABLSTAT | [JBP] Original Meter Reading Status | S_ABLSTAT | CHAR | 2 | ||
S_V_ZWSTAND | [JBP] Orig. MR: Decimal Places Before Meter reading | S_V_ZWSTAND | DEC | 9 | ||
S_N_ZWSTAND | [JBP] Decimal Places of Meter Readings for Original MR | S_N_ZWSTAND | DEC | 8 | ||
S_V_ZWSTNDAB | [JBP] Predecimal Places of Billed MR for Original MR | S_V_ZWSTNDAB | DEC | 9 | ||
S_N_ZWSTNDAB | [JBP] Decimal Places of Billed Orginal Meter Reading | S_N_ZWSTNDAB | DEC | 8 | ||
REMOVED | [JBP] Status Indicator: MR Result Suppressed | REMOVED | CHAR | 2 | ||
BP | Selection of Billing Period: Standard or JBP | BP | CHAR | 2 | ||
REM_ABLBELNR | [JBP] Suppressed MR Document Number | REM_ABLBELNR | CHAR | 40 | * | |
REM_ABLESER | Meter Reader Number of Suppressed Meter Reading | R_ABLESER | CHAR | 6 | * | |
S_ADATSOLL | Scheduled meter reading date | ADATSOLL | DATS | 16 | ||
S_ZVBL_BEZDAT | Scheduled meter reading date for base meter reading | E_ZVBL_BEZDAT | DATS | 16 | ||
.INCLUDE | CI_EABL | 0 | ||||
.INCLUDE | ISU_AMIINCL | 0 | ||||
AMS | Advanced Metering System | E_AMI_AMS | CHAR | 8 | TEAMI_AMS | |
TRANSSTAT | Transfer Status Code | E_AMI_MR_TRANSSTAT | CHAR | 10 | ISU_F4_AMITRSTAT | |
TRANSTSTAMP | UTC Time Stamp in Long Form (YYYYMMDDhhmmssmmmuuun) | TIMESTAMPL | DEC | 11 | ||
SOURCESYST | Source System From Which Data is Requested | E_AMI_SOURCESYST | NUMC | 2 | ||
.INCLUDE | QNT_DATA | ISU_QNT_DATA | 0 | |||
QNT | Quantity Determined from Meter Reading in Internal Format | E_QD_QNT | DEC | 16 | ||
QDSTAT | Status of Quantity Determination | E_QD_STAT | CHAR | 4 | ||
QDPROC | Qty Determination Procedure During Meter Reading / Billing | E_QD_PROC_MR | NUMC | 4 | ||
PREV_MRDOC | Internal ID of Previous Meter Reading Result Document | E_QD_PREV_MRDOC | CHAR | 40 | * | |
.INCLUDE | COLOGRP_MR_I | 0 | ||||
COLOGRP | Colocation group for Meter Reading | E_COLOGRP_MR | CHAR | 24 |