TE410 - Parameters for MR Data Processing
Parameters for MR Data Processing information is stored in SAP table TE410.
It is part of development package EE17 in software component IS-U-DM-MR. This development package consists of objects that can be grouped under "IS-U: Meter Reading Data Entry".
It is part of development package EE17 in software component IS-U-DM-MR. This development package consists of objects that can be grouped under "IS-U: Meter Reading Data Entry".
Fields for table TE410
Field Name | Description | Is Key | Data Element | Data Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | Client | X | MANDT | CLNT | 6 | T000 |
BUKRS | Company Code | X | BUKRS | CHAR | 8 | T001 |
SPARTE | Division | X | SPARTE | CHAR | 4 | TSPA |
PROTMS | Log automatic estimation | PROTMS | CHAR | 2 | ||
EABLAEND | Meter reading results can be changed | EABLAEND | CHAR | 2 | ||
EABLBELG | Indicator: do not print meter reading document in spool | EABLBELG | CHAR | 2 | ||
E_ZUKERF | Limitation on MR date of MR result | E_ZUKERF | CHAR | 2 | ||
UEFAKTOR1 | Overestimation factor in percent | UEFAKTOR1 | DEC | 2 | ||
UEFAKTOR2 | Overestimation factor in percent | UEFAKTOR2 | DEC | 2 | ||
KARSCHLABL | Interval for suppression of meter readings for final MR | KARSCHLABL | NUMC | 6 | ||
KON_REL | Auto. reflect device replacement in meter reading results | DEVREPLACE | CHAR | 2 | ||
DUMMYES | Create dummy EABL for meter reading order creation | DUMMYES | CHAR | 2 | ||
MSPRUMZ | No automatic disconnection for move-in/out | MSPRUMZ | CHAR | 2 | ||
LEISTMS | Estimation of watt and resetting registers | LEISTMS | CHAR | 2 | ||
KOABLVOR | Prepare control reading | KOABLVOR | CHAR | 2 | ||
PRORUECK | Resetting for control/interim meter reading | PRORUECK | CHAR | 2 | ||
SERVICEABW | Create service notification or order | SERVICEABW | CHAR | 2 | ||
IGNESTIRESULTS | Ignore Estimated Meter Reading Results During Extrapolation | IGNESTIRESULTS | CHAR | 2 | ||
INTERVUPLPER | MROC interval for upload of periodic results | INTERVUPLPER | NUMC | 6 | ||
INTFROMESTIRES | Also Derive from Estimated MR Results | INTFROMESTIRES | CHAR | 2 | ||
KAUFERSTRUHANL | No meter reading order creation for inactive installations | KAUFERSTRUHANL | CHAR | 2 | ||
PROPOSE_MOVEIN | Display default move-in value | PROPOSE_MOVEIN | CHAR | 2 | ||
INTV_PROP_MOVEIN | Interval for determining default value for move-in | INTV_PROP_MOVEIN | NUMC | 6 | ||
INTV_INTERNET | Interval for internet meter reading | INTV_INTERNET | NUMC | 6 | ||
TREAT_INTERNETMR | Upload from Internet Meter Reading | TREAT_INTERNETMR | CHAR | 2 | ||
NOCHGE_BACKBMRES | No change to billed reading during floating backbilling | CHGE_BACKB_MRRES | CHAR | 2 | ||
NOCHGE_DPCMRES | No Change to Billed Meter Reading for Dynamic Period Control | CHGE_DPC_MRRES | CHAR | 2 | ||
INTV_DEVREPL | Device replacement interval | INTV_DEVREPL | NUMC | 6 | ||
DEVREPL_DIALOG | Device Replacement (Dialog) Automatically Taken into Account | DEVREPLACE_DIALOG | CHAR | 2 | ||
INTV_INTERIM | Interval for Interim Meter Reading | INTV_INTERIM | NUMC | 6 | ||
TREAT_INTERIMMR | Handling of Interim Meter Reading with Billing During Upload | TREAT_INTERIMMR | CHAR | 2 | ||
AMI_DER_INTERVAL | Interval for Derivation During AMI Entry | E_AMI_MR_DERINTERVAL | NUMC | 6 | ||
QDPLCHECK | Validation for Final Quantity | E_QDPLCHECK | CHAR | 2 |