/PRA/SB_RNAWC_V - Residue and NGL Actual at WC Level
Residue and NGL Actual at WC Level information is stored in SAP table /PRA/SB_RNAWC_V.
It is part of development package /PRA/VERSIONING in software component IS-OIL-PRA. This development package consists of objects that can be grouped under "Main package for Versioning".
It is part of development package /PRA/VERSIONING in software component IS-OIL-PRA. This development package consists of objects that can be grouped under "Main package for Versioning".
Fields for table /PRA/SB_RNAWC_V
Field Name | Description | Is Key | Data Element | Data Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | Client | X | MANDT | CLNT | 6 | |
CA_VERSION_ID | Unique Version ID | X | /PRA/VERSION_ID | CHAR | 64 | |
DN_NO | Delivery network number | X | OIU_DN_NO | CHAR | 40 | OIU_PR_DN |
WL_NO | Well ID number | X | OIU_WL_NO | CHAR | 30 | OIU_PR_WELL |
WC_NO | Well Completion Number | X | OIU_WC_NO | CHAR | 10 | OIU_PR_WC |
MATNR | Material Number | X | MATNR | CHAR | 80 | OIU_CM_MAT_PRCD |
CT_NO | Contract Number | X | OIU_CT_NO | CHAR | 20 | OIU_RV_CT |
SA_DT | Sales date | X | OIU_SA_DT | DATS | 16 | |
OWN_NO | PRA owner | X | OIU_OWN_NO | CHAR | 20 | LFA1 |
OWN_INT_TYPE_CD | Participant Interest Type | X | OIU_PART_INT_TYPE | CHAR | 4 | OIU_CM_PINTTY |
OWN_ISQ_NO | Owner Interest Sequence Number | X | OIU_OWN_ISQ_NO | CHAR | 4 | |
ORIG_MP_NO | Original measurement point number | X | OIU_ORIG_MP_NO | CHAR | 40 | OIU_PR_MP |
TRNSP_NO | Transporter number | X | OIU_TRNSP_NO | CHAR | 20 | |
ACTL_VOL_U | Actual Volume Units | OIU_ACTL_VOL_U | UNIT | 6 | T006 | |
ACTL_VOL | Actual Volume | OIU_ACTL_VOL | QUAN | 7 | ||
HEAT_VAL_U | Heating Value Unit | OIU_HEAT_VAL_U | UNIT | 6 | T006 | |
HEAT_VAL | Heating value | OIU_HEAT_VAL | QUAN | 7 | ||
ACTL_ENERGY_U | Actual Energy Unit | OIU_ACTL_ENERGY_U | UNIT | 6 | T006 | |
ACTL_ENERGY | Actual Energy | OIU_ACTL_ENERGY | QUAN | 7 | ||
WG_EQUIV_QY_U | Wet gas equivalent unit | OIU_WG_EQUIV_U | UNIT | 6 | T006 | |
WG_EQUIV_QY | Wet Gas Equivalent Unit | OIU_WG_EQUIV | QUAN | 7 | ||
BASIS_QY_U | Basis Quantity UoM | OIU_BASIS_QY_U | UNIT | 6 | T006 | |
BASIS_QY | Basis Quanity | OIU_BASIS_QY | QUAN | 7 | ||
.INCLUDE | OIU_CT_SEC_ENTL | 0 | ||||
ENTL_CT_VOL | Entitled Contract Volume | OIU_ENTL_CT_VOL | QUAN | 7 | ||
ENTL_CT_VOL_U | Volume Unit | OIU_VOL_U | UNIT | 6 | ||
ENTL_CT_ENER | Entitled Contract Energy | OIU_ENTL_CT_ENER | QUAN | 7 | ||
ENTL_CT_ENER_U | Energy quantity unit | OIU_ENERGY_U | UNIT | 6 | * | |
.INCLUDE | OIU_CREATION | 0 | ||||
OIU_CRUSER | Name of Person Responsible for Creating the Object | ERNAM | CHAR | 24 | ||
OIU_TIMESTAMP | UTC Time Stamp in Short Form (YYYYMMDDhhmmss) | TZNTSTMPS | DEC | 8 |